Direct Reading Optical Emission Spectrometer 170-670nm Wavelength Range Argon Filled

  • 1
  • 2
  • 3

Price : Bulk discount

Place of Origin : CHINA

Brand Name : TESTECH

Certification : CE; ISO

MOQ : 1 Piece

Packaging Details : In Carton

Delivery Time : 3-7 days

Payment Terms : T/T, Credit Card, Paypal, Western Union

Supply Ability : 5000pcs/month

Model Number : VL-4000

warranty : 1 years

customized support : OEM

weight : 60kg

type : X-ray Spectrometer, Other, Atomic Emission Spectrometer

Product name : Optical Emission Spectrometer

Model : VL-4000

Wavelength Range : 170 -670 nm, --

Diameter of Rowland circle : 350mm

Detector : Multi high resolution CCD detector

Temperature autocontrol : 34℃±0.5℃

Optical grating groove : 3600 l/mm

Level One spectral dispersive power : 1.2 nm/mm

Benchtop Model High : 340mm

Length : 657mm

Size : 657*670*340mm

Contact Now

VL-4000 Direct Reading Optical Emission Spectrometer 170 -670nm Wavelength Range Argon Filled For Metal Content Analysis

VL-4000 spectrometer is designed for industrial analytical laboratories of mechanical engineering, metallurgical and metal processing factories. Spectrometer is capable to replace a whole laboratory for identification chemical composition of metals and alloys, significantly affecting the quality of products. VL-4000 represents the best solution for customers who need speed, high technical characteristics, reliability and high accuracy of the determination of the total elemental composition of metal.

VL-4000 spectrometer can be used in the quantitative analysis of sold metal samples and grade identification. Optical system with CCD detector, spectral range covers all typical materials. Instruments equipped with argon flush spark machine, open design spark stand is suitable for the analysis of samples with different shapes and sizes.

Technical Specifications
  • Paschen-Runge Mount Structure, Rowland circle optical system.
  • Diameter of Rowland circle:350mm
  • Wavelength Range:170 – 670 nm
  • Detector:Multi high resolution CCD detector
  • Optical chamber temperature:Temperature autocontrol:34℃±0.5℃
  • Optical grating groove:3600 l/mm
  • Level One spectral dispersive power:1.2 nm/mm
  • External Incident window, convenient cleaning and replacement
  • Excellent drift correction, thanks to automatic peak-finding(accuracy of 0.1 pixels)
Sizes
  • Benchtop Model High: 340mm,Length:657mm, Width:670mm, Weight:60kg
Argon Requirements
  • Pure argon, 99.999%; argon valve (specifically with pressure reducing valve)
  • Air pressure> 4MPa; export equipment pressure 0.5MPa
  • Copper transmission
Standard Configuration list for VL-4000 Optical Emission Spectrometer
No. ITEMS UNIT QTY REMARK
1 VL-4000 Optical Emission Spectrometer PCS 1  
2 Analytical Base PCS 1 Fe Base
3 Analytical Curve PCS 1  
4 Re – Cal Sample PCS 1  
5 Pneumatic pipe and fitting M 2  
6 Oxygen pressure reducing valve and fitting PCS 1  
7 Power wire PCS 1  
8 Signal transmission wire PCS 1  
9 Operation software PCS 1  
10 User manual PCS 1  
11 Qualified certificate PCS 1  
12 Complete set packing list PCS 1  
13 List of tools and spare parts PCS 1  
14 Warranty Bill PCS 1  
15 Delivery form for installation and acceptance PCS 2  
Analytical Program
Item Element Fe-001
Low Alloy Steel
1 C 0.006-1.19
2 Si 0.013-3.86
3 Mn 0.034-2.2
4 P 0.0019-0.13
     
5 S 0.0009-0.364
6 Cr 0.016-4.83
7 Ni 0.0082-4.4
8 Mo 0.004-4.19
9 Al 0.0021-1.27
10 Cu 0.0032-0.8
11 Co 0.004-0.504
12 Ti 0.001-1.18
13 Nb 0.004-1.04
14 V 0.0082-0.9
15 W 0.005-2.07
16 Pb 0.003-0.26
17 B 0.0003-0.019
18 Sn 0.0016-0.039
19 As 0.007-0.174
20 Bi 0.0019-0.021
21 Zr 0.004-0.57
22 Ca 0.0004-0.0015
23 Fe Balance
Main core components of VL-4000 spectrometer
No. Item Brand Company or Origin
1 Linear array CCD Toshiba Japan
2 Optical grating Zeiss Germany
3 Optical lenses Zeiss Germany
4 Optical fiber Agilent USA
5 Slit lenoxlaser USA
6 Filter TDK Japan
7 Pressure sensor SSI Canada
8 Solenoid valve Burkert Germany
9 Light source module CREATE -
10 System control module CREATE -
11 Data collection module CREATE -
12 Excitation stand module CREATE -
13 Software CREATE -

Product Tags:

Direct Reading optical emission spectrometer

      

670nm optical emission spectrometer

      

170nm oes spectrometer

      
Buy cheap Direct Reading Optical Emission Spectrometer 170-670nm Wavelength Range Argon Filled product

Direct Reading Optical Emission Spectrometer 170-670nm Wavelength Range Argon Filled Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Testech Group Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)